Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: ADC
TEST F2 Reader Installation Guides


TODO


Known Models

AD235
ADG235
ADG235D
AG235BH
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 0016 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only

P/N: C-5414
F2 Standard Mounting Bracket
Sheet metal base
Qty: 1
P/N: C-5416
Screw
8-32" x 3/8" - Button - Torx
Qty: 2
P/N: C-5436
Screw
10-32 x 1" - Pan MS
Qty: 2
P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6601
Spacer
F2 Dexter Vault Filler Plate
Qty: 1
P/N: C-6701
Adapter Plate
F1 to F2
Qty: 1

  1. Place the C-5414 Mounting Bracket on top of the C-6601 Spacer Plate. 

  2. Place both Mounting Bracket and Spacer Plate over the mounting hole previously used by the coin drop.
  3. Place the C-6701 Adapter Plate on the opposite side of the machine panel and secure in place using the C-5416 Screws.
  4. Place the C-5710 Rubber Grommet into the circular opening of the C-5414 Mounting Bracket.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 3
P/N: C-5210
Power Adapter Harness
CGI
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6348
Coin Sense Harness (SA)
ADC Phase 5
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6348 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5344
Machine Start Harness
ADC Phase 5
Qty: 1

  1. Connect the C-5344 Machine Start Harness to the Coin 1 connection on the Machine Control Assembly.

Optional: Stack Add-on Installation

Pulse

P/N: C-5344
Machine Start Harness
ADC Phase 5
Qty: 1
P/N: C-6348
Coin Sense Harness (SA)
ADC Phase 5
Qty: 1
P/N: C-6400
F2, Stack Add On Board - SLV
Pulse / SingleVend
Qty: 1

  1. Run C-5344 Machine Start Harness and C-6348 Coin Sense Harness to the second Machine Control Assembly.
  2. Connect C-5344 Machine Start Harness to the Coin 1 connection and the C-6348 Coin Sense Harness to the coin drop for the second Machine Control Assembly.
  3. Connect the C-6400 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Port 2 on the reader.
    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to the Stack Add-on Board.
  4. Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.
  5. Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the C-5344 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-6348 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5344)

  1. Equipment Type: SingleVend
  2. Pulse Length: 60