Make: Wascomat
FasCard Coin & Card kit depends on how the coin drop is connected to the dryer computer:

- If connected via bare wires to a terminal block then use:
F1: K-5754-TER
F2: K-6078
LC: K-0360
- If connected via card edge connector to dryer computer then use:
F1: K-5754
F2: K-6061
LC: K-0370
TEST F2 Reader Installation Guides


TODO


Known Models

TD3030
TD3535
TD4545
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 0394 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only

P/N: C-0941
Vault Cover
3-7/8" x 3-1/2"
Qty: 1
P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove existing coin box.

  2. Bend the side tabs of the C-0941 Vault Cover outward and install into the coin vault. The tabs should snap into place securing the bracket.

  3. Place the C-6700-TEMP Drill Template on the desired mounting location.

  4. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  5. Refer to FasCard Mounting Guide for further instructions.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 2
P/N: C-5336
Power Adapter Harness
Dexter Stack
Qty: 1
P/N: C-5500-84
Power Extension Harness
84"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5101 Power Adapter Harness to the power distribution panel inside the machine.

    1. 120vac: Connect the brown and blue wires to connector #2 closest to outside of machine and #4 on terminal side closest to circuit board.

    2. 240vac: Connect the brown and blue wires to connectors 3 and 5 on the terminal side closest to the circuit board.

    3. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-5101  Power Adapter Harness to the C-5602 Power Converter.

  3. Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory Edge Connector

P/N: C-6357
Coin Sense Harness (SA)
can use C-6357-144
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6357 Coin Sense Harness to the harness connected to the Coin Drop.

Coin Drop: Factory Terminal Connector

P/N: C-6358
Coin Sense Harness (SA)
TD, F2
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6358 Coin Sense Harness to the harness connected to the Coin Drop.
    1. Connect the coin drop wires to the matching colored wires on the coin sense harness.

Connect Machine Interface Harness

Pulse - Edge Connector

P/N: C-5353R1
Machine Start Harness (SA)
40" - LaundryLux
Qty: 1

  1. Connect the C-5353R1 Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.

Pulse - Terminal Connector

P/N: C-5356
Machine Start Harns (rare)
TD Pulse
Qty: 1

  1. Connect the C-5356 Machine Start Harness to the Positions 2 and 3 on the terminal block.

Pulse - Terminal Connector with Block

P/N: C-5313
Terminal Block (rare)
for Laundrylux TD Dryers
Qty: 1
P/N: C-5356
Machine Start Harns (rare)
TD Pulse
Qty: 1

  1. Attach the C-5313 Terminal Block to the Machine Control Assembly.
  2. Connect the C-5356 Machine Start Harness to the Positions 2 and 3 on the terminal block.
    1. Terminal block positions are numbered 0-6. Position 0 is closest to the board edge.

Optional: Stack Add-on

Coin and Card - Edge Connector

P/N: C-5353R1-144
Machine Start Harness (SA)
144" - LaundryLux
Qty: 1
P/N: C-6357-144
Coin Sense Harness (SA)
144" LaundryLux Edge Connect
Qty: 1
P/N: C-6400
F2, Stack Add On Board - SLV
Pulse / SingleVend
Qty: 1

  1. Connect the C-6400 Stack Add-On Board to the MLV connection (Port 5 as show below in Step 6.) on the F2 reader.
  2. Connect the C-5353R1-144 Machine Start Harness to the Coin 1 connector on the lower pocket's Machine Control Assembly.
    1. Connect the opposite end to the C-6400 Stack Add-On Board.
  3. Connect the C-6357-144 Coin Sense Harness to the lower pocket's Coin Drop.
    1. Connect the opposite end to port 4 (Coin 2 sense harness connection.) on the F2 reader.

Coin and Card - Terminal Connector

P/N: C-5356-40
Machine Start Harns
TD
Qty: 1
P/N: C-6358-40
Coin Sense Harness (SA)
TD
Qty: 1
P/N: C-6400
F2, Stack Add On Board - SLV
Pulse / SingleVend
Qty: 1

  1. Connect the C-6400 Stack Add-On Board to the MLV connection (Port 5 as show below in Step 6.) on the F2 reader.
  2. Connect the C-5356-40 Machine Start Harness to the Coin 1 connector on the lower pocket's Machine Control Assembly.
    1. Connect the opposite end to the C-6400 Stack Add-On Board.
  3. Connect the C-6358-40 Coin Sense Harness to the lower pocket's Coin Drop.
    1. Connect the coin drop wires to the matching colored wire on the coin sense harness. 
    2. Connect the opposite end to port 4 (Coin 2 sense harness connection.) on the F2 reader.

Card Only - Edge Connector

P/N: C-5353R1-144
Machine Start Harness (SA)
144" - LaundryLux
Qty: 1
P/N: C-6400
F2, Stack Add On Board - SLV
Pulse / SingleVend
Qty: 1

  1. Connect the C-6400 Stack Add-On Board to the MLV connection (Port 5 as show below in Step 6.) on the F2 reader.
  2. Connect the C-5353R1-144 Machine Start Harness to the Coin 1 connector on the lower pocket's Machine Control Assembly.
    1. Connect the opposite end to the C-6400 Stack Add-On Board.

Card Only - Terminal Connector

P/N: C-5313
Terminal Block (rare)
for Laundrylux TD Dryers
Qty: 1
P/N: C-5356-144
Machine Start Harns (rare)
TD Pulse
Qty: 1
P/N: C-6400
F2, Stack Add On Board - SLV
Pulse / SingleVend
Qty: 1

  1. Connect the C-6400 Stack Add-On Board to the MLV connection (Port 5 as show below in Step 6.) on the F2 reader.
  2. Connect the C-5356-40 Machine Start Harness to the Coin 1 connector on the lower pocket's Machine Control Assembly.
    1. Connect the opposite end to the C-6400 Stack Add-On Board.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of theCoin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500-84 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5353R1; 5356)

  1. Equipment Type: SingleVend
  2. Pulse Length: 500