Overview

Equipment Details


Average Installation Time


On This Page

Make: LG
Giant-C Plus Dryer
Giant-C Wifi Dryer
TEST F1 Reader Installation Guides


TODO


Known Models

GDL1329CED3
GDL1329CES3
GDL1329CEW3
GDL1329CGD3
GDL1329CGS3
GDL1329CGS5
GDL1329CGW3
GDL1329CGW3LG
GDL1329QES3
GDL1329QEW3
GDL1329QEWE
GDL1329QGD3
GDL1329QGS3
GDL1329QGW3
GDP1329CED2
GDP1329CES
GDP1329CEW
GDP1329CEW2
GDP1329CGS2
GDP1329CGU
GDP1329LGS
GDP1329QES
GDP1329QES2
GDP1329QGD2
GDP1329QGW2
TEST F1 Reader Installation Guides



This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

Part IDDescriptionImage
C-5001
F1 FasCard Reader

Recommended Tools and Supplies (Not Included)

See 2034 FasCard F1 Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5800
F1 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Card Ready

P/N: C-5633-R1
Label - Build: TK
3.5 x 1.75
Qty: 1
P/N: C-5800
F1 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

  4. If needed, use C-5633-R1 Label to cover the factory card reader slot.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 3
P/N: C-5210
Power Adapter Harness
CGI
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-5250
Coin Sense Harness
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5272
Machine Start Harness
LG
Qty: 1

  1. Connect the C-5257 Machine Start Harness to the Coin 1 harness previously connected to the coin drop.

Serial

P/N: C-5274R1
Machine Start Harness
LG
Qty: 1

  1. Connect the C-5274R1 Machine Start Harness to the Serial connector on the communication harness.

Connect and Mount Reader

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness:
    1. For C-5272 pulse harness setups connect to port 2 (Pulse Connection Port) as shown in the image above.
    2. For C-5274R1 serial harness setups connect to port 1 (Serial Connection Port) as shown in the image above.
  3. Connect the free end of the C-5250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Extension Harness to port 4 ( Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5272)

  1. Equipment Type: SingleVend
  2. Pulse Length: 30

Serial (C-5274R1)

  1. Equipment Type: Giant-C

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.