Overview

Equipment Details


Average Installation Time


On This Page

Make: [VARIES]
TEST F1 Reader Installation Guides


TODO


Known Models

BDE807*F
BDE907*F
BDE907WF
BDET07*F
BDEX07*F
BDGT09*F
BDGT09WF
BFEX07*F
BFGX09*F
HDE007*F
HDE107*F
HDE907*F
HDET07*F
HDET07WF
HDEY07*F
HDEY07WF
HDEZ07*F
HDG009*F
HDG109*F
HDG109WF
HDG909*F
HDG909WF
HDGT07WF
HDGT09*F
HDGT09WF
HDGY09*F
HDGY09WF
HDGZ09*F
JDE807*F
JDE907*F
JDE907WF
JDG809*F
JDG909*F
KFEG17NF
KFET17NF
KFEY17NF
KFGG19NF
KFGT19NF
KFGY19NF
SDE007*F
SDE107*F
SDE307*F
SDE407*F
SDE507*F
SDE607*F
SDE707*F
SDE807*F
SDE907*F
SDE907QF
SDE907WF
SDEA07*J
SDEB07*J
SDEC07*J
SDEF07*J
SDEH07*J
SDET07*F
SDET07WF
SDEX07*F
SDEY07*F
SDEZ07*F
SDG009*F
SDG109*F
SDG109WF
SDG309*F
SDG409*F
SDG509*F
SDG609*F
SDG709*F
SDG809*F
SDG909*F
SDG909WF
SDGA09*J
SDGB09*J
SDGC09*J
SDGF09*J
SDGH09*J
SDGT09*F
SDGT09WF
SDGX09*F
SDGY09*F
SDGZ09*F
SFE107*F
SFE407*F
SFE507*F
SFE707*F
SFEB07*J
SFEF07*J
SFET07*F
SFET07WF
SFEX07*F
SFEY07*F
SFEY07WF
SFEZ07*F
SFG109*F
SFG409*F
SFG509*F
SFG709*F
SFGB09*J
SFGF09*J
SFGT09*F
SFGX09*F
SFGY09*F
SFGY09WF
SFGZ09*F
UDE007*F
UDE807*F
UDG009*F
UDG809*F
TEST F1 Reader Installation Guides



This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

Part IDDescriptionImage
C-5001
F1 FasCard Reader

Recommended Tools and Supplies (Not Included)

See 3198 FasCard F1 Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5014
Reader Base & Gasket
F1
Qty: 1
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5702
Chase Nipple
3/4"
Qty: 1
P/N: C-5703
Lock Nut
3/4" - 102-S
Qty: 1
P/N: C-5705
Screw
8 x 1-1/2 Plastite
Qty: 2

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Card Ready Models

P/N: C-5801
F1 Reader Mounting Kit
Front
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Coin Slide Models

P/N: C-0141
Screw
8-32 x 1-1/2" - Cap
Qty: 2
P/N: C-0301
Topload Mounting Bolt
Qty: 1
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5760
Metercase Bracket
Coin Slide Ready Machine
Qty: 1

  1. Remove existing coin box and coin slide.

  2. Install C-5760 Metercase Bracket over the front of the metercase and secure using the C-0301 Mounting Bolt.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 3
P/N: C-5210
Power Adapter Harness
CGI
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Optical  - MDC and EDC Controls

P/N: C-5250
Coin Sense Harness
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5250 Coin Sense Harness to the harness connected to the Coin Drop.

Coin Drop: Mechanical - Coin Slide

P/N: C-5253
Coin Sense Harness
28"
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5253 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse - Optical Coin Sensors - EDC Controls

P/N: C-5300-NC
Machine Start Harness
can use C-5300-NC-144
Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the XXXX connector on the Machine Control Assembly.

Pulse - Mechanical Coin Sensors - Coin Slide

P/N: C-5256
Machine Start Harns (pulse)
20" - Male taps, Rq. Female
Qty: 1

  1. Connect the C-5256 Machine Start Harness to the harness previously connected to the micro switch on the coin slide/drop.

Pulse - Serial Communication - MDC Controls

P/N: C-0110-CP
Jumper Plug
Enables card mode on pre-ACA
Qty: 1
P/N: C-0110-TOP
Machine Start Harness
can use C-0110-TOP-144
Qty: 1

  1. Connect the C-0110-TOP Machine Start Harness to the H5 connection on the Machine Control Assembly.

Serial - MDC Controls

P/N: C-0110-CP
Jumper Plug
Enables card mode on pre-ACA
Qty: 1
P/N: C-0110-TOP
Machine Start Harness
can use C-0110-TOP-144
Qty: 1

  1. Remove the existing Alliance Jumper Plug at H8 and connect the C-0110-CP Jumper Plug.
  2. Connect the C-0110-TOP Machine Start Harness to the H5 connection on the Machine Control Assembly.

Connect and Mount Reader

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

  1. Feed remaining harness ends through the mounting hole as described in F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness to the appropriate port.
    1. For pulse start harnesses (white connector), connect to port 2 (Pulse Connection Port) as shown in the image above.
    2. For serial start harnesses (black connector), connect to port 1 (Serial Connection Port) as shown in the image above
  3. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the F1: FasCard Reader Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-0110-TOP, C-5300-NC, C-5256)

  1. Equipment Type: SingleVend
  2. Pulse Length: 80

Serial (C-0110-TOP)

  1. Equipment Type: Alliance MDC Small Dryer

    Page not found for multiexcerpt macro.