Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: [VARIES]
TEST F2 Reader Installation Guides


TODO


Known Models

BTEBCASP173TW01
BTEBXASP433AW01
BTGBCASP113TW01
BTGBXASP303AW01
HTEBCASP173TW01
HTEBXASP133DW01
HTEBXASP283CW01
HTEBXASP293CW01
HTEBXASP543DW01
HTGBCASP113TW01
HTGBXASP093CW01
HTGBXASP123DW01
HTGBXASP543DW01
STEBCASP173TW01
STEBXASP133DW01
STEBXASP173TW01
STEBXASP303UW01
STEBXASP433AW01
STEBXASP543DW01
STEBXASP543ZW01
STGBCASP113TW01
STGBXASG113TW01
STGBXASP113TW01
STGBXASP123DW01
STGBXASP303AW01
STGBXASP303ZW01
STGBXASP543DW01
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3250 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Connect Power

Dryer Control

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 3
P/N: C-5210
Power Adapter Harness
CGI
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Washer Control

P/N: C-6204
Power Adapter Harness
F2 12vDC Power Harness
Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the Machine Control Assembly.
    1. Connect the green wire to a chassis ground.
  2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6250
Coin Sense Harness
can use C-6250-144
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5300-NC
Machine Start Harness
can use C-5300-NC-144
Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.

Serial - Dryer Control

P/N: C-0110-CP
Jumper Plug
Enables card mode on pre-ACA
Qty: 1
P/N: C-0110-TOP
Machine Start Harness
can use C-0110-TOP-144
Qty: 1

  1. Connect the C-0110-TOP Machine Start Harness to the H4 connector on the Machine Control Assembly.

Serial - Washer Control

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness:
    1. If following steps for a serial Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
    2. If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the Power Harness to port 1 (Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

Dryer Control

  1. Power off the machine.
  2. Connect the C-0110-CP Jumper Plug to the H6 connection on the Machine Control Assembly.
  3. Power on the machine.

Washer Control

ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5300-NC)

  1. Equipment Type: SingleVend
  2. Pulse Length: 80

Serial (C-0110-TOP)

  1. Equipment Type: Alliance MDC Small Dryer

Serial (C-5240)

  1. Equipment Type: Alliance ACA H7S Front Load Washer A1 - MDC II