Equipment Details


Average Installation Time


On This Page

Make: Dexter
TEST F2 Reader Installation Guides


TODO


Known Models

WCVD18KCS10
WCVD18KCS10
WCVD18KCS10
WCVD18KCS10
WCVD18KCS10
WCVD18KCS100000
WCVD18KCS10EC
WCVD18KCS10EC
WCVD18KCS10EC
WCVD18KCS10EC
WCVD18KCS10EC
WCVD18KCS10USA0
WCVD18KCS12
WCVD18KCS12
WCVD18KCS12
WCVD18KCS12
WCVD18KCS12
WCVD18KCS120000
WCVD18KCS12CS100000
WCVD18KCS12EC1X
WCVD18KCS12SSBS
WCVD18KCS12USA
WCVD18KCS12USA
WCVD18KCS12USA
WCVD18KCS12USA
WCVD18KCS12USX
WCVD18KCS12USX
WCVD20KCS12
WCVD20KCS12USSZ
WCVD25KCS10
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS12
WCVD25KCS120000
WCVD25KCS120000
WCVD25KCS12EC
WCVD25KCS12US
WCVD25KCS12US
WCVD25KCS12USA
WCVD25KCS12USA
WCVD25KCS12USA
WCVD25KCS12USA
WCVD30KCS12
WCVD30KCS12USSZ
WCVD40KCDS12
WCVD40KCDS12
WCVD40KCS10
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12
WCVD40KCS12000
WCVD40KCS120000
WCVD40KCS12EC
WCVD40KCS12EC
WCVD40KCS12EC
WCVD40KCS12EC1X
WCVD40KCS12US
WCVD40KCS12US
WCVD40KCS12US
WCVD40KCS12USA
WCVD40KCS12USA
WCVD40KCS12USA
WCVD40KCS12USA
WCVD40KCS12USA
WCVD40KCS12USA
WCVD40KCS12USA
WCVD50KCS12
WCVD55KCS000000
WCVD55KCS10
WCVD55KCS12
WCVD55KCS12
WCVD55KCS12
WCVD55KCS12
WCVD55KCS12
WCVD55KCS12
WCVD55KCS120000
WCVD55KCS12EC
WCVD55KCS12EC
WCVD55KCS12EC1X
WCVD55KCS12SSBS
WCVD55KCS12US
WCVD55KCS12USA
WCVD55KCS12USA
WCVD55KCS12USA
WCVD55KCS12USA
WCVD55KCS12USA
WCVD55KCS12USA
WCVD55KCS12USSZ
WCVD55KCS12USX
WCVD55KCS12USXX
WCVD55KCS12XXXX
WCVD75KCS12
WCVD75KCS120000
WCVD75KCS12EC1X
WCVD75KCS12USA0
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3279 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Coin Ready

P/N: C-0144
Screw
8-32 x 2" - Flat
Qty: 2
P/N: C-0905
Drop Cover
2-3/8" x 4-5/8"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1
P/N: C-6936
F2, Sm Vault Mount Bracket
Qty: 1

  1. Install the C-5702 Chase Nipple into the C-5414 F2 Mounting Bracket using the C-5703 Nut.
  2. Feed the remaining harness ends through the open face of the Coin Vault.
  3. Spread the C-6936 Vault Mount Bracket wings outward before insertion to lock bracket into place.
  4. Feed remaining harness ends through the C-6936 Vault Mount Bracket.
  5. Insert the C-6936 Vault Mount Bracket into the Coin Vault.
  6. Feed the remaining harness ends through the combined C-5414 F2 Mounting Bracket.
  7. Secure the combined C-5414 F2 Mounting Bracket to the C-6939 Vault Mount Bracket with the C-0144 Screws.

Card Only - Card Ready

P/N: C-5035
Label
3-7/8" x 3-1/4"
Qty: 1
P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Place C-5035 Label over card slot opening.
  4. Refer to FasCard Mounting Guide for further instructions.

Connect Power

P/N: C-5338
Power Adapter Harness
WCAD
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5338 Power Adapter Harness to the power distribution panel inside the machine or tapping as needed.
    1. 120vac- Connect Brown and Blue wires to connector #2 closest to outside of machine and #4 on terminal side closest to circuit board.
    2. 240vac- Connect Brown and Blue wires to connectors 3 and 5 on the terminal side closest to the circuit board.
    3. Secure the green wire beneath the ground screw.
  2. Connect the opposite end of the C-5338 Power Adapter Harness to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6253
Coin Sense Harness
28"
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6253 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5254
Machine Start Harness
Dexter Stack Dryer
Qty: 1

  1. Connect the C-5254 Machine Start Harness to the P2 connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the C-5254 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-6253 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5254)

  1. Equipment Type: SingleVend
  2. Pulse Length: 55