Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: Continental
TEST F1 Reader Installation Guides


TODO


Known Models

EH020C1132111
EH020CA
EH020CA131112
EH020CA13112
EH020CA1321121
EH020CA13211210
EH020CA1324121
EH020CA13241210
EH020CA1521111011
EH020X
EH020X113211110
EH020X1132111101
EH020X1132112101
EH020X132112101
EH020X2132111101
EH020XA
EH020XA123112101
EH020XA132112
EH020XA1321120
EH020XA1321121
EH020XA13211210
EH020XA132112100
EH020XA132112101
EH020XA1321121011
EH020XA132412101
EH020XA182112101
EH025CA1321121
EH030C11311111
EH030C1132111
EH030C113211110
EH030CC
EH030X
EH030X1
EH030X113211101
EH030X11321111
EH030X113211110
EH030X1132111100
EH030X1132111101
EH030X1132112101
EH030X1182111101
EH030X2111101
EH030X213211101
EH030X31821111011
EH030XA1132111101
EH040C113
EH040C1132
EH040C1132111
EH040C113211110
EH040C1132111100
EH040X
EH040X11320111101
EH040X1132111
EH040X113211101
EH040X1132111011
EH040X11321111
EH040X113211110
EH040X1132111101
EH040X11321111011
EH040X1182111101
EH040XA
EH040XA1132111100
EH055C213
EH055CT13
EH055X113211110
EH055X1132111100
EH055X1132111101
EH060C
EH060X
EH060X1132111
EH060X11321110
EH060X1132111101
EH060X11321111011
EH060X1132111110
EH060X1182111101
EH060X21321111
EH060X2132111101
EH060X2182111101
EH060X3182111101
EH080X
EH080X11321111011
EH080X21
EH080X2111101
EH080X213211101
EH080X2132111101
EH080X21321111011
EH090C
EH090C1132111100
EH090X
EH090X21
EH090X2111101
EH090X211321111011
EH090X2123211101
EH090X2132
EH090X2132111
EH090X213211101
EH090X2132111011
EH090X21321111
EH090X2132111101
EH090X21321111011
EH090X3182111101
EH130X
EH130X2182111
EH130X21821111011
EH130X31821110011
EM025CA1321121
EM025CA1321121W
EM025CA1321191
EM055C
EM055C1132111
EM055C11321111
TEST F1 Reader Installation Guides



This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

Part IDDescriptionImage
C-5001
F1 FasCard Reader

Recommended Tools and Supplies (Not Included)

See 3285 FasCard F1 Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5800
F1 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - 20lb Model

P/N: C-0902
Mounting Bracket
Contintental 20#
Qty: 1
P/N: C-1042
Nut
8-32 - Kep
Qty: 4
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5752
Screw
8-32 x 3" - Flat
Qty: 2

  1. Remove existing coin box.

  2. Install the C-0902 Mounting Bracket into the Coin Vault. Use C-1042 Kep Nuts to secure to Coin Vault.

  3. Apply C-5027 Label to the top of the reader.

Card Only - 30lb Plus Model

P/N: C-0903
Mounting Bracket
Continental E-Series
Qty: 1
P/N: C-1042
Nut
8-32 - Kep
Qty: 4
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5752
Screw
8-32 x 3" - Flat
Qty: 2

  1. Remove existing coin box.

  2. Install the C-0903 Mounting Bracket into the Coin Vault. Use C-1042 Kep Nuts to secure to Coin Vault.

  3. Apply C-5027 Label to the top of the reader.

Connect Power

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 2
P/N: C-5336
Power Adapter Harness
Dexter Stack
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5336 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
    1. Secure the ground wire beneath a chassis screw.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-5332
Coin Sense Harness (SA)
CGI EM
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5332 Coin Sense Harness to the harness connected to the Coin Drop.

Coin Drop: Aftermarket - Imonex

P/N: C-5382
Coin Sense Harness
Imonex EM100/EM3
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5382 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5330
Combination Harness
CGI EM
Qty: 1

  1. Connect the C-5330 Machine Start Harness to the coin acceptor connector on the Machine Control Assembly.

Serial

P/N: C-0114-MLV
Machine Start Harness
Continental (serial)
Qty: 1

  1. Connect the C-0114-MLV Machine Start Harness to the RJ-11 port on the Serial Communication Board.

Connect and Mount Reader

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness:
    1. If following steps for a serial Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
    2. If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-5500 Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse

  1. Equipment Type: SingleVend
  2. Pulse Length: 500

Serial (C-0114-MLV)

  1. Equipment Type: Continental ProfitPlus Washer

    Page not found for multiexcerpt macro.