Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: [VARIES]
Alliance ACA Top-Load Washer
bypass
TEST F1 Reader Installation Guides


TODO


Known Models

HWNBC2PP115TW01
HWNBY2PP115TW01
HWNBY2PT115TW01
HWNBY2SB115EW01
HWNBY2SP115TW01
HWNKC210115TW01
HWNKC2P1115TW01
HWNKC2SP115PW01
HWNKC2SP115TW01
HWNKC2ST115PW01
HWNKC2ST115TW01
HWNKE2SP115EW01
HWNKX2SP115CW01
HWNKY2SB115CW01
HWNKY2SP115CW01
HWNKY2ST115CW01
HWNSX2PP115TW01
KWNBX2SP115TW01
KWNSX2PP115TW01
KWNSX2SP115TW01
PWNBC2PP115TW02
PWNBX2PP115TG02
SWNNC25P113TW01
SWNNC2HP113TW15
SWNNC2HP115TW 02
SWNNC2HP115TW01
SWNNC2HP115TW02
SWNNC2HT115TW01
SWNNC2SP113TQ01
SWNNC2SP113TW01
SWNNC2SP113TW02
SWNNC2SP115TQ01
SWNNC2SP115TW01
SWNNC2SP115TW02
SWNNX2AP113TW15
SWNNX2HP115TW01
SWNNX2SP113TW02
SWNNX2SP115CW01
SWNNX2SP115TW01
SWNNX2SP115TW02
SWNNY2HP115TW01
SWNNY2SG115TW01
SWNNY2SP113TW01
SWNNY2SP115PW01
SWNNY2SP115TW01
SWNNY2ST113TW01
SWNNY2ST115TW01
SWNSX2SP115TW01
SWNSX2SP115TW02
TEST F1 Reader Installation Guides



This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

Part IDDescriptionImage
C-5001
F1 FasCard Reader

Recommended Tools and Supplies (Not Included)

See 3569 FasCard F1 Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5800
F1 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Coin Ready (Standard Metercase)

P/N: C-0141
Screw
8-32 x 1-1/2" - Cap
Qty: 2
P/N: C-1059
Nut
10-32 - Kep
Qty: 2
P/N: C-1070-W
Washer - Build: XCH
1/4" x 1" O.D.
Qty: 2
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5365
Bypass Harness
Alliance Coin Vault Bypass
Qty: 1
P/N: C-5761
Metercase Bracket
Coin Drop Ready Machine
Qty: 1

  1. Remove any previously installed Coin Drop and Coin Box.
  2. Install the C-5761 Mounting Bracket into the Coin Vault and secure by using C-1070-W Washer and C-1059 Nut.

Card Only - Coin Ready (High Capacity Metercase)

P/N: C-0141
Screw
8-32 x 1-1/2" - Cap
Qty: 2
P/N: C-1059
Nut
10-32 - Kep
Qty: 2
P/N: C-1070-W
Washer - Build: XCH
1/4" x 1" O.D.
Qty: 2
P/N: C-5027
Label
Credit Card Logo
Qty: 1
P/N: C-5760-A
Alliance Adapter Bracket
Mounts C-5760 to MeterCase
Qty: 1
P/N: C-5762
Metercase Bracket - High Cap
Coin Slide Ready Machine
Qty: 1

  1. Remove any previously installed Coin Drop and Coin Box.
  2. Attach the C-5760-A Adapter Bracket to the C-5762 Mounting Bracket.
  3. Install the C-5762 Mounting Bracket into the Coin Vault and secure by using C-1070-W Washer and C-1059 Nut.

Card Only - Card Ready

P/N: C-5800
F1 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Connect Power

P/N: C-6204-40
Power Adapter Harness
F2, 12vDC Pow Harness - 40"
Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 Connection on the Machine Control Assembly.
    1. Connect the green wire to a chassis ground.
  2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-5250
Coin Sense Harness
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-5250 Coin Sense Harness to the harness connected to the Coin Drop.

Coin Slide Hybrid: Factory

P/N: C-5253
Coin Sense Harness
28"
Qty: 1

  1. Disconnect the connections from the Coin Switch.
  2. Connect the C-5256 Coin Sense Harness to the micro switch.

Connect Machine Interface Harness

Serial

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connection on the Machine Control Assembly.

Pulse - Coin Drop

P/N: C-5300-NC
Machine Start Harness
can use C-5300-NC-144
Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the Machine Control Assembly where the coin drop was previously connected.

Pulse - Coin Slide Hybrid

P/N: C-5256
Machine Start Harns (pulse)
20" - Male taps, Rq. Female
Qty: 1

  1. Connect the C-5256 Machine Start Harness to the Harness where the micro switch was previously connected.

Connect and Mount Reader

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the Machine Start Harness.
    1. If following steps for a serial Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.
    2. If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-6204-40 Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

  1. Ensure DIP switch #3 is set to the ON position on the Machine Control Assembly.

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.


Serial (C-5240)

  1. Equipment Type: Alliance ACA H7S Top Load Washer A1 - MDC II

Pulse (C-5256, C-5300-NC)

  1. Equipment Type: SingleVend