Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: [VARIES]
Alliance ACA Small Dryer (Single)
TEST F2 Reader Installation Guides


30 mins


Known Models

HDCBYRGS113CW01
HDEBCAGS173TW01
HDEBCRGS173TW01
HDEBYAGS173CW01
HDEBYAGS173TW01
HDEBYRGS173TW01
HDGBCAGS113TW01
HDGBCRGF113TW01
HDGBCRGS113TW01
HDGBYAGS113CW01
HDGBYAGS113TW01
HDGBYRGS1130T01
HDGBYRGS113TW01
KDESXAGS173YW01
KDESXRGS173TW01
SDENCAGS173TW01
SDENCRGS173TW01
SDENCRGS173TW02
SDENYAGS153TW01
SDENYAGS173TW01
SDENYRGS173TW01
SDGNCRGS113TW02
SDGNYAGS113TW01
SDGNYRGS113TW01
SDGSXRGS113TW01
SDGSXRGS113TW02
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3581 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Card Ready

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place C-5763 TWL Bracket in the intended mounting location. Using the bracket, mark the location of all four mounting holes.
  2. Drill a hole at each marked location using a 3/16" drill bit.
  3. Attach C-5414 Mounting Bracket to the front of C-5763 using two C-5420 screws
  4. Mount the C-5763 TLW Bracket using four C-5420 Screws and fasten from the inside of the panel.

Card Only - Rear Control Coin Slide Metercase

P/N: C-0301
Topload Mounting Bolt
Qty: 1
P/N: C-6760
Metercase Bracket
Coin Slide Ready Machine
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove existing coin box and coin slide.

  2. Attach C-5414 Standard Bracket to the C-6760 Metercase Bracket using the C-5702 Chase Nipple and C-5703 Nut.

  3. Insert C-6760 Metercase Bracket into the metercase and secure using C-0301 Topload Mounting Bolt.

Card Only - Rear Control Coin Drop Metercase

P/N: C-1059
Nut
10-32 - Kep
Qty: 2
P/N: C-1070-W
Washer - Build: XCH
1/4" x 1" O.D.
Qty: 2
P/N: C-5365
Bypass Harness
Alliance Coin Vault Bypass
Qty: 1
P/N: C-5760-A
Alliance Adapter Bracket
Mounts C-5760 to MeterCase
Qty: 1
P/N: C-6762
Metercase Bracket
Coin Slide Ready Machine
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove any previously installed Coin Drop and Coin Box.
  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
  3. Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket.
  4. Install the C-6762 Mounting Bracket into the Coin Vault and secure by using C-1070-W Washer and C-1059 Nut.

Card Only - Coin Ready 10 Degree Control Panel 

P/N: C-1059
Nut
10-32 - Kep
Qty: 2
P/N: C-1070-W
Washer - Build: XCH
1/4" x 1" O.D.
Qty: 2
P/N: C-5365
Bypass Harness
Alliance Coin Vault Bypass
Qty: 1
P/N: C-6765-W
F2 Mounting Bracket
10 Degree - White Finish
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove existing coin box and coin drop.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
  3. Install the C-6765-W Metercase Bracket and secure to the machine using the C-1059 Kep Nut and C-1070-W Washer.

  4. Attach the C-5414 F2 Mounting Bracket to the C-6765-W Metercase Bracket using C-5702 Chase Nipple and C-5703 Lock Nut.

Connect Power

Non-ACA Controls

P/N: C-5101
Spade Taps
18-14 AWG
Qty: 3
P/N: C-5210
Power Adapter Harness
CGI
Qty: 1
P/N: C-5500
Power Extension Harness
25.5"
Qty: 1
P/N: C-5602R1
Power Converter
SMT-012-018VW
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

ACA Controls

P/N: C-6204-40
Power Adapter Harness
F2, 12vDC Pow Harness - 40"
Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the machine control assembly. 

    1. Secure the green wire beneath the ground screw.

  2. Connect the opposite end of the C-6204-40  Power Adapter Harness (3-pin molex) to the F2 reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6250
Coin Sense Harness
can use C-6250-144
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Coin Slide: Factory

P/N: C-6253
Coin Sense Harness
28"
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6253 Coin Sense Harness to the harness connected to the Coin Slide Switch.

Connect Machine Interface Harness

Pulse - Coin Drop

P/N: C-5300-NC
Machine Start Harness
can use C-5300-NC-144
Qty: 1

  1. Connect the C-5300-NC Machine Start Harness to the harness previously connected to the coin drop..

Pulse - Coin Slide

P/N: C-5256
Machine Start Harns (pulse)
20" - Male taps, Rq. Female
Qty: 1

  1. Connect the C-5256 Machine Start Harness to the harness previously connected to the Coin Slide Switch.

Serial

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connection on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the FasCard Mounting Guide.
  2. Connect the free end of the Machine Start Harness.
    1. If following steps for a serial Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
    2. If following steps for a pulse Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the Coin Sense Harness to port 3 (Coin 1 Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the Power Extension Harness to port 1 (Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5300-NC or C-5256)

  1. Equipment Type: Singlevend
  2. Pulse Length: -80

Serial (C-5240)

  1. Equipment Type: Alliance ACA H7S Small Dryer A1- MDC II