Page tree
Skip to end of metadata
Go to start of metadata

Overview

Equipment Details


Average Installation Time


On This Page

Make: [VARIES]
Alliance ACA Tumbler Dryer (Stack)
TEST F2 Reader Installation Guides


TODO


Known Models

HTT30NBCANBG3N0000
HTT30NBCANXG3N0000
HTT30NBY0NBG3N0000
HTT30NBY0NBS3NC000
HTT30NBY0NXG3N0000
HTT30NBY0NXG3W0000
HTT30NNC0NBG3W00A0
HTT30NNC0NBS3NC0C0
HTT30NNCANBG3NC0
HTT30NNCANBG3NC0C0
HTT30NNCANBG3W0000
HTT30NNCANXG3N0000
HTT30NNCANXG3N00C0
HTT30NNCANXG3NC0C0
HTT30NNY0NBG3N0000
HTT30NNY0NBS3NC0C0
HTT30NNY0NXG3N0000
HTT30NWCANBG3N0000
HTT30NWCANBG3N00A0
HTT30NWCANBG3NC000
HTT30NWCANBG3NC0A0
HTT30NWCANBG3NC0C0
HTT30NWCANBG3W0000
HTT30NWCANXG3NC0C0
HTT30NWCARXS5NC0A0
HTT30NWY0NBG3N0000
HTT30NWY0NBG3N00A0
HTT30NWY0NBG3N00C0
HTT30NWY0NBG3NC0A0
HTT30NWY0NBG3NC0C0
HTT30NWY0NBS3N0000
HTT30NWY0NXG3N00A0
HTT30NWY0NXG3NC0A0
HTT30NWY0RBS5NC0C0
HTT30NWY0RXS5NC000
HTT30NWY0RXS5NC0C0
HTT45LWCARXG5W0000
HTT45NBCANXG3N0000
HTT45NBCANXG3W0000
HTT45NBCANXS3N0000
HTT45NBY0NBS3NC000
HTT45NBY0NXG3N0000
HTT45NBY0NXG3W0000
HTT45NBY0NXS3NC000
HTT45NNC0NXG3W00A0
HTT45NNC0NXS3NC0C0
HTT45NNCANXG3N0000
HTT45NNCANXG3N00A0
HTT45NNCANXG3NC0C0
HTT45NNY0NXG3N0000
HTT45NNY0NXS3NC0C0
HTT45NWCANXG3N0000
HTT45NWCANXG3NC000
HTT45NWCANXG3NC0A0
HTT45NWCANXG3NC0C0
HTT45NWCANXG3W0000
HTT45NWCARXS3NC000
HTT45NWCARXS5NC0A0
HTT45NWY0NBG3NC0C0
HTT45NWY0NX53NC0C0
HTT45NWY0NX63NC000
HTT45NWY0NXG3N0000
HTT45NWY0NXG3N00A0
HTT45NWY0NXG3N00C0
HTT45NWY0NXG3NC000
HTT45NWY0NXG3NC0A0
HTT45NWY0NXG3NC0C0
HTT45NWY0NXG3W0000
HTT45NWY0NXG5NC0A0
HTT45NWY0NXS3N0000
HTT45NWY0NXS3NC000
HTT45NWY0NXS3NC0C0
HTT45NWY0RBS5NC0C0
HTT45NWY0RXG3NC0C0
HTT45NWY0RXG5W0000
HTT45NWY0RXS5NC000
HTT45NWY0RXS5NC0A0
HTT45NWY0RXS5NC0C0
KTT30NBCANBH3N0000
KTT30NBCANXH3N0A00
KTT30NBCANXS3W00
KTT30NBCANXS3W0000
KTT30NBY0NXH3N0000
KTT30NBYANBH3N00
KTT30NBYANBH3N000
KTT30NNY0NNH3N00
KTT45NBCANXH3N00
KTT45NBCANXH3N0000
KTT45NBCANXS3N00
KTT45NBY0NXH3N0000
KTT45NNCANXS3W00
KTT45NNCANXS3W000
KTT45NNCANXS3W0000
KTT45NNY0NXH3N00
KTT45NNY0NXH3N0000
PTT30NNCANBG3N0000
PTT45NNCANXG3N0000
STT30NBCANBG3N0000
STT30NBCANBG3W0000
STT30NBCANXG3N0000
STT30NBCANXG3W0000
STT30NBDANBG3W0000
STT30NBY0NBG3N0000
STT30NBY0NXG3N0000
STT30NBY0NXG3W0000
STT30NNCANBG3N0000
STT30NNCANBG3W0000
STT30NNCANXG3N0000
STT30NNDANXG3N0000
STT30NNY0NXG3N0000
STT30NVCANBH4NC000
STT30NVCANDH4NB000
STT30NVY0NBH4NC000
STT30NWCANBG3N0000
STT30NWCANXG3N0000
STT30NWX0NBG3N0000
STT45NBCANXG3N0000
STT45NBCANXG3W0000
STT45NBY0NX63N0000
STT45NBY0NXG3N0000
STT45NBY0NXG3W0000
STT45NNCANXG3N0000
STT45NNCANXG3W0000
STT45NNCANXS3W0000
STT45NNCARXS5NC000
STT45NNDANXG3N0000
STT45NNY0NXG3N0000
STT45NNY0NXZ3N0000
STT45NVCANXH4NC000
STT45NVX0NXH4NC000
STT45NVX0RXH5NC000
STT45NVY0NXH4NC000
STT45NVY0RXH5NC000
STT45NVY0RXH5NC000]
STT45NWCANXG3N0000
STT45NWCANXG3NC000
STT45NWCANXH4NC000
STT45NWY0NXG3N0000
TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3584 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only - Card Ready

P/N: C-1060
Screw - Build: TK
8-32 x 3/8" - Zinc
Qty: 2
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1
P/N: C-6970
F2, Bracket
Alliance Card Ready
Qty: 1

  1. Install the C-6970 Alliance Mounting Bracket into the opening on the control panel for mounting card readers and coin drops.
  2. Attach the C-5414 F2 Mounting Bracket to the C-6970 Alliance Mounting Bracket and secure using the C-1060 Screws.
  3. Refer to F2 FasCard Reader Mounting Guide for further instructions.

Card Only - Coin Ready

P/N: C-0144
Screw
8-32 x 2" - Flat
Qty: 2
P/N: C-5033
Label
4-5/8" x 3-1/2"
Qty: 1
P/N: C-5365
Bypass Harness
Alliance Coin Vault Bypass
Qty: 1
P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1
P/N: C-6936
F2, Sm Vault Mount Bracket
Qty: 1

  1. Remove existing coin box.

  2. Install the C-5365 Bypass Harness by removing the coin vault switch and connecting the spade terminal connections to C-5365 Bypass Harness.
  3. Bend the side tabs of the C-6936 Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Attach the C-5414 F2 Mounting Bracket to the Coin Vault Bracket using C-0144 screws.

Connect Power

P/N: C-6204-40
Power Adapter Harness
F2, 12vDC Pow Harness - 40"
Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-6204-40 Power Adapter Harness (12VDC power) to the H10 connection on the Machine Control Assembly.
  2. Secure the green wire beneath the ground screw.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6250
Coin Sense Harness
can use C-6250-144
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse or Serial

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Optional: Stack Add-on Installation

Pulse and Serial - Coin and Card

P/N: C-5240-144
Machine Start Harness
144" for Alliance ACA
Qty: 1
P/N: C-6250-144
Coin Sense Harness
144" length
Qty: 1
P/N: C-6401
F2, Stack Add On Board - MLV
Serial / MultiVend
Qty: 1

  1. Run C-5240-144 Machine Start Harness and C-6250-144 Coin Sense Harness to the second Machine Control Assembly.
  2. Connect C-5240-144 Machine Start Harness to the H3 connection and the C-6250-144 Coin Sense Harness to the Coin 1 connection on the second Machine Control Assembly.
  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.
  4. Connect the Coin Sense Harness connected to the upper pocket Coin Drop to port 3 (Coin 1 Sense Harness Connection Port) on the F2 reader.
  5. Connect the Coin Sense Harness connected to the lower pocket Coin Drop to port 4 (Coin 2 Sense Harness Connection Port) on the F2 reader.

Pulse and Serial - Card Only (Coin Ready Models)

P/N: C-0940
Vault Cover
3-7/8" x 2-3/4"
Qty: 1
P/N: C-5033
Label
4-5/8" x 3-1/2"
Qty: 1
P/N: C-5240-144
Machine Start Harness
144" for Alliance ACA
Qty: 1
P/N: C-6401
F2, Stack Add On Board - MLV
Serial / MultiVend
Qty: 1

  1. Install C-0940 Vault Cover into the coin vault for the secondary control.
  2. Run C-5240-144 Machine Start Harness to the second Machine Control Assembly.
  3. Connect C-5240-144 Machine Start Harness to the H3 connection on the second Machine Control Assembly.
  4. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

Pulse and Serial - Card Only (Card Ready Models)

P/N: C-5240-144
Machine Start Harness
144" for Alliance ACA
Qty: 1
P/N: C-6401
F2, Stack Add On Board - MLV
Serial / MultiVend
Qty: 1

  1. Run C-5240-144 Machine Start Harness to the second Machine Control Assembly.
  2. Connect C-5240-144 Machine Start Harness to the H3 connection on the second Machine Control Assembly.
  3. Connect the C-6401 Stack Add-on Board to port 5 (Serial Connection Port) on the F2 reader.
    1. Connect the Machine Start Harness connected to the upper pocket Machine Control Assembly to Unit 1 on the Stack Add-on Board.
    2. Connect the Machine Start Harness connected to the lower pocket Machine Control Assembly to Unit 2 on the Stack Add-on Board.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.
  3. Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-6204-40 Power Extension Harness to port 1 (C-5500 Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5240)

  1. Equipment Type: SingleVend
  2. Pulse Length: -80

Serial (C-5240)

  1. Equipment Type: