TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3589 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

ERROR: Kit 0 Does Not Exist

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only

ERROR: Kit 0 Does Not Exist

TODO

Connect Power

ERROR: Kit 0 Does Not Exist

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document by connecting the C-5203 Power Adapter Harness to terminal strip or contacts L1 and L2.
    1. Connect the ground wire to a chassis screw.
    2. Connect the opposite end to the C-5602 Power Converter.
  2. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

Coin Drop: Factory

ERROR: Kit 0 Does Not Exist

  1. Disconnect the Coin Eye Harness from the Coin Drop.
  2. Connect the C-6307 Coin Sense Harness to the Coin Eye Sensor connected to the Coin Drop.

Coin Drop: Factory

ERROR: Kit 0 Does Not Exist

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6251 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse - Standard Harness

ERROR: Kit 0 Does Not Exist

  1. Connect the C-5344 Machine Start Harness to the Coin Drop connector on the Coin Counting Board.

Pulse - Combination Harness

ERROR: Kit 0 Does Not Exist

  1. Connect the C-6307 Machine Start Harness to the Coin Counting Board Harness where the coin drop was previously connected.
  2. The remaining tap connections should be inserted between the coin block solenoid and the existing harness connected to the solenoid.
    1. Disconnect the existing harness and match the male/female connectors on that side and the solenoid side of the circuit.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F1: FasCard Reader Mounting Guide.
  2. Connect the free end of the C-XXXX Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-XXXX Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-XXXX Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown in the image above.
  5. Secure the FasCard reader to base as described in the FasCard Mounting Guide.

Machine Configuration

TODO

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-6307)

  1. Equipment Type: SingleVend
  2. Pulse Length: 80