TEST F2 Reader Installation Guides

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Recommended Tools and Supplies (Not Included)

See 3631 F2 Reader Install Guide for more information.

Installation

    Page not found for multiexcerpt macro.
The page: null was not found. Please check/update the page name used in the 'multiexcerpt-include' macro.

Install Mounting Hardware

Coin and Card

P/N: C-5710
Rubber Grommet
3/4"
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

Card Only

P/N: C-0144
Screw
8-32 x 2" - Flat
Qty: 2
P/N: C-5033
Label
4-5/8" x 3-1/2"
Qty: 1
P/N: C-5365
Bypass Harness
Alliance Coin Vault Bypass
Qty: 1
P/N: C-6601
Spacer
F2 Dexter Vault Filler Plate
Qty: 1
P/N: C-6602
F2, Large Vault Mount
Qty: 1
P/N: C-6801
F2 Reader Mounting Kit
Universal
Qty: 1

  1. Remove existing coin box and coin drop.

  2. Disconnect terminal connections from vault service switch and bridge using C-5365 Bypass Harness.
  3. Bend the side tabs of the C-6602 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.

  4. Align the holes on the C-5414 Mounting Bracket to those on the C-6601 Spacer Plate. Align so that the spacer plate is between the mounting bracket and the machine. Run reader power and start harness through the large opening in the center of the bracket and plate.

  5. Attach to the C-6602 Vault Bracket using the C-0144 screws

Connect Power

P/N: C-6204-40
Power Adapter Harness
F2, 12vDC Pow Harness - 40"
Qty: 1

  1. Connect the C-6204-40 12VDC Power Harness to the H10 connection on the Machine Control Assembly.
    1. Connect the green wire to a chassis ground.
  2. The remaining end (3-pin molex) connects directly to the rear of the F2 FasCard Reader.

Connect Coin Sense Harness

Coin Drop: Factory

P/N: C-6250
Coin Sense Harness
can use C-6250-144
Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6250 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

Pulse

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Serial

P/N: C-5240
Machine Start Harness
can use C-5240-144
Qty: 1

  1. Connect the C-5240 Machine Start Harness to the H3 connector on the Machine Control Assembly.

Connect and Mount Reader

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through the mounting hole as described in the F2 Reader Mounting Guide.
  2. Connect the free end of the C-5240 Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above. 
  3. Connect the free end of the C-6250 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the free end of the C-6204-40 Power Harness to port 1.
  5. Secure the FasCard reader to base as described in the F2 Reader Mounting Guide.

Machine Configuration

ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

FasCard Admin Site Configuration

Use the following settings depending on the Machine Start Harness used.

Pulse (C-5240)

  1. Equipment Type: SingleVend
  2. Pulse Length: 80

Serial (C-5240)

  1. Dryer Equipment Type: Alliance Midas - Tumbler Dryer
  2. Washer-Extractor Equipment Type: Alliance Midas - Washer-Extractor