Overview and Equipment Information

This document is intended to guide the user through installation utilizing the kit numbered according to the document title. A list of associated equipment models including control information and additional installation notes can be found below.

Kit Installation Notes

Status: Active

Product: FasCard F2
Manufacturer: Dexter
Start Harness: 4-pin single row flat connector
Interface Type: Pulse
Install Type: Coin and Card
Actuation: Coin Drop - Imonex EM100/EM3
Coin Sense: N/A
Mounting: Surface Mount
Chassis: N/A
Readers: 1 Reader
Machine Control: N/A


This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Installation Kit

QTYPart NumberDescriptionImage
1C-5254Machine Start Harness
1C-5710Rubber Grommet
1C-6209F2, Power Adapter Hrns - Dex
1C-6382Coin Sense Harness
1C-6801F2 Reader Mounting Kit

Recommended Tools and Supplies (Not Included)

See F2 Reader Mounting Guide for more information.

Installation

Confirm machine power is disconnected before beginning installation!

Use caution and appropriate protection to prevent hand and eye injury during installation!

Step 1 - Install Mounting Bracket

C-6700-TEMPC-6801
Drill Template
F2 Reader Mounting Kit

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.
  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.
  3. Refer to F2 Reader Mounting Guide for further instructions.

Step 2 - Connect Power

C-6209
F2, Power Adapter Hrns - Dex

  1. Connect the C-6209 Power Adapter Harness to the 24v terminal connections near the front control panel. The remaining cable end connects to the FasCard reader after installation.

Step 3 - Connect Coin Sense Harness

C-6382
Coin Sense Harness

  1. Disconnect the Coin Drop from the Machine Control Assembly.
  2. Connect the C-6382 Coin Sense Harness to the harness connected to the Coin Drop.

Step 4 - Connect Machine Start Harness

C-5254
Machine Start Harness

  1. Connect the C-5254 Machine Start Harness to the Machine Control Assembly serial connection port.

Step 5 - Connect and Mount FasCard Reader

C-0127-MLVC-5401C-6209C-6382
Machine Start Harness
F2 FasCard Reader
F2, Power Adapter Hrns - Dex
Coin Sense Harness

  1. Feed remaining harness ends through mounting hole as described in F2 Reader Mounting Guide.
  2. Connect the free end of the C-5254 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image below.
  3. Connect the free end of the C-6382 Coin Sense Harness to port 3 (Coin 1 Connect Port) as shown in the image below.
  4. Connect the free end of the C-6209 Power Extension Harness to port 1 (Power Connection Port) as shown in the image below.
  5. Connect FasCard reader to base as described in the F2 Reader Mounting Guide.
  6. Program the card reader address as described here: How to Program Address on a FasCard Reader.

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

Associated Equipment Models

MakeModelPulse LengthSensorControlNotes
DexterDC##X2##-###C2#-#####-##A50FalseSingle-Vend (Pulse)Notes
DexterDC##X2##-###C2#-#####-##X50FalseSingle-Vend (Pulse)Notes