Overview and Equipment Information

This document is intended to guide the user through installation utilizing the kit numbered according to the document title. A list of associated equipment models including control information and additional installation notes can be found below.

Kit Installation Notes

Status: Active

Product: FasCard F2
Manufacturer: Maytag
Start Harness: 6-pin (2x3) molex connector
Interface Type: Pulse
Install Type: Card Only
Actuation: Coin Drop - Factory
Coin Sense: N/A
Mounting: Metercase Bracket
Chassis: Small Chassis - Rear Control
Readers: 1 Reader
Machine Control: Mechanical


ACA machines using a serial configuration require dip switch 3 on the Machine Control Board to be set to the 'ON' position. Leave all other dip switches as is.

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses. It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Required Hardware

Card Reader

One of the following readers.

Part IDDescriptionImage
C-3001
LC WiFi Reader
Front/Vertical Mount
C-3002
LC WiFi Reader
Top/Horizontal Mount
C-5401
F2 FasCard Reader
Front Mount
C-5402
F2 FasCard Reader
High Front/Top Mount
C-5403
FLEX Reader
Front/Vertical Mount
C-5404
FLEX Reader
Top/Horizontal Mount

Installation Kit

QTYPart NumberDescriptionImage
1C-0116-MECMachine Start Harness
1C-0301Topload Mounting Bolt
3C-5101Spade Taps
1C-5210Power Adapter Harness
1C-5602Power Converter
1C-6801F2 Reader Mounting Kit
1C-6911F2 Metercase Bracket

Recommended Tools and Supplies (Not Included)

See F1 Reader Mounting Guide for more information.

Installation

Confirm machine power is disconnected before beginning installation!

Use caution and appropriate protection to prevent hand and eye injury during installation!

Step 1 - Install Mounting Bracket

C-0301C-5771
Topload Mounting Bolt
Metercase Bracket

  1. Install the C-5771 Metercase Bracket over the Metercase.

Step 2 - Connect Power

C-5101C-5210C-5500C-5602
Spade Taps
Power Adapter Harness
Power Extension Harness
Power Converter

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Step 3 - Connect Machine Start Harness

C-0116-MEC
Machine Start Harness

  1. Connect the C-0116-MEC Machine Start Harness (short side) at the Coin Box area.
    1. Connect the long side of the harness under the faceplate, near display/controls.

Step 4 - Connect and Mount FasCard Reader

C-0116-MECC-5500
Machine Start Harness
Power Extension Harness

Item No.ComponentNotes
1Power Connection PortUtilizes the same power harnesses as the first generation FasCard reader.
2Pulse Connection PortConnection point for pulse machine start harnesses.
3Coin 1 Connection PortThis is the connection point for the harness input associated with Coin 1.
4Coin 2 Connection PortThis is the connection point for the harness input associated with Coin 2.
5Serial Connection PortThis is the connection point for serial machine start harnesses.

  1. Feed remaining harness ends through mounting hole as described in F1 Reader Mounting Guide.
  2. Connect the free end of the C-0116-MEC Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-5500 Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown in the image above.
  4. Connect FasCard reader to base as described in the FasCard Mounting Guide.
  5. Program the card reader address as described here: How to Program Address on a FasCard Reader.

Associated Equipment Models

MakeModelPulse LengthSensorControlNotes
WhirlpoolCAM2742TQ*40000FalseSingle-Vend (Pulse)
WhirlpoolCAM2762TQ*40000FalseSingle-Vend (Pulse)