Kit Installation Notes

Installation Kit

Recommended Tools and Supplies (Not Included)

See F1 Reader Mounting Guide for more information.

Installation



Step 1 - Install Mounting Bracket

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.
  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.
  3. Refer to FasCard Mounting Guide for further instructions.

Step 2 - Connect Power

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided or by connecting directly to the power terminals at L1 and L2.
  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.
  3. Connect the C-5500-84 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Step 3 - Connect Coin Sense Harness

  1. Disconnect the existing wires from the Coin Switch.
  2. Connect the C-5253 Coin Sense Harness to the harness connected to the Coin Switch.

Step 4 - Connect Machine Start Harness

  1. Connect the C-5356 Machine Start Harness to the wires previously disconnected from the Coin Switch.

Step 5 - Connect and Mount FasCard Reader

  1. Feed remaining harness ends through mounting hole as described in FasCard Mounting Guide.
  2. Connect the free end of the C-5356 Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.
  3. Connect the free end of the C-5253 Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.
  4. Connect the C-5500 Power Extension Harness to port 4 (C-5500 Power Harness Connection Port) as shown above.
  5. Connect FasCard reader to base as described in the FasCard Mounting Guide.
  6. Program the card reader address as described here: How to Program Address on a FasCard Reader.